The European Union Energy Performance of Buildings Directive (EPBD) contains a range of provisions to improve the energy performance of new and existing buildings. The EPBD obliges specific forms of information and advice on energy performance to be provided to building purchasers, tenants and users for consideration in property transactions. A Building Energy Rating (BER) is an indication of the energy performance of a building represented in units of kWh/m2/year. A BER is based on the characteristics of major components of the building. The BER certificate indicates the annual primary energy usage and carbon dioxide emissions associated with the provision of space heating, water heating, ventilation, lighting, and associated pumps and fans. The average annual primary energy use figures and carbon dioxide emissions are not based on actual energy use and emissions data.
These Background notes provide a very general overview together with some specific information on the detailed tables in the release. The SEAI website should be consulted for detailed information on the non-domestic energy assessment procedure (NEAP).
The figures in this release will be updated on a quarterly basis. Changes to data for the previous quarters will arise mainly from some buildings having another BER audit undertaken and the previous certificate being marked as expired.
Full site surveys have to be carried out for New-final and Existing building assessments. New-provisional ratings do not require a site survey as the assessment is done based on design stage plans – new provisional ratings have been excluded from this release. Some buildings are excluded from the EPBD requirements: national monuments; protected structures; places of worship; temporary buildings; industrial and agricultural buildings not intended for occupancy and below a specified installed heating capacity; and buildings with a total useful floor area of less than 50 square metres. Short-term lettings are not exempt. Some BER audits have been excluded from tables due to insufficient data.
A BER for new non-domestic buildings was introduced in July 2008 and for selling or renting of existing non-domestic buildings in January 2009. New regulations came into effect in January 2013 requiring the inclusion of BER information in property sale and rental advertisements.
On 24 May 2026 the Building Energy Rating (BER) scale was modified in line with new EU wide regulations under the Energy Performance of Buildings Directive (EPBD). The scale has been simplified from fifteen points to eight (A0, A, B, C, D, E, F, G). A0 is a new rating which accounts for an absence of fossil fuel demand and carbon emissions as well as the primary energy kWh/m2/year.
BERs awarded before 24 May 2026 will remain valid for ten years and are included in the tables of this release. To allow direct comparisons with data from both scales, ratings from the old scale have been converted directly to their equivalent letter in the new scale.
The data have not been adjusted to represent all non-domestic buildings in the State and hence the tables only represent buildings that have been assessed.
The BER rating scale is divided into categories from G (largest primary energy usage) to an A1 rating (lowest primary energy usage). Energy consumption is expressed in kWh per square metre of floor area of the building per year (kWh/m2/year) and CO2 emissions are expressed in kilograms of carbon dioxide per square metre per year (kgCO2/m2/year). For the purposes of this release, the numbered sub-ratings have been combined into single letter grades.The certificate is valid for 10 years unless changes are made to the building.
The BER for non-domestic or non-residential buildings is based on the predicted primary energy consumption of a building (kWh/m2/year), assuming a standardised pattern of use. To allow different building types to be compared on the same scale, the non-domestic BER uses different thresholds for different building types (described in Table A as of Q2 2026). The scale prior to 24 May 2026 used a different method, comparing the ratio of the actual building energy efficiency to an ideal notional building of the same type. These calculations are defined by the Non-Domestic Energy Assessment Procedure (NEAP), using the Simplified Building Energy Model (SBEM). More details on this assessment are available in the SEAI’s NEAP modelling guide here.
| Building Type | A0* | A | B | C | D | E | F | G |
|---|---|---|---|---|---|---|---|---|
| Residential Institutions - Universities and colleges | 70 | 140 | 280 | 420 | 560 | 700 | 840 | 840 |
| Emergency services | 275 | 350 | 700 | 1050 | 1400 | 1750 | 2100 | 2100 |
| General Assembly and Leisure plus Night Clubs and Theatres | 140 | 185 | 370 | 555 | 740 | 925 | 1110 | 1110 |
| General Industrial and Special Industrial Groups | 115 | 175 | 350 | 525 | 700 | 875 | 1050 | 1050 |
| Hotels | 190 | 270 | 540 | 810 | 1080 | 1350 | 1620 | 1620 |
| Non-residential Institutions - Community/Day Centre | 85 | 110 | 220 | 330 | 440 | 550 | 660 | 660 |
| Non-residential Institutions - Libraries Museums and Galleries | 90 | 140 | 280 | 420 | 560 | 700 | 840 | 840 |
| Non-residential Institutions - Primary Health Care Building | 70 | 120 | 240 | 360 | 480 | 600 | 720 | 720 |
| Offices and Workshop businesses | 40 | 120 | 240 | 360 | 480 | 600 | 720 | 720 |
| Others - Miscellaneous 24hr activities | 500 | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 6000 |
| Others - Passenger terminals | 90 | 170 | 340 | 510 | 680 | 850 | 1020 | 1020 |
| Residential Institutions - Hospitals | 210 | 300 | 520 | 740 | 960 | 1180 | 1400 | 1400 |
| Residential spaces | 65 | 125 | 250 | 375 | 500 | 625 | 750 | 750 |
| Restaurant and Cafes/Drinking Establishments and Hot Food takeaways | 160 | 250 | 500 | 750 | 1000 | 1250 | 1500 | 1500 |
| Retail and Financial/Professional services | 70 | 180 | 360 | 540 | 720 | 900 | 1080 | 1080 |
| Schools | 30 | 60 | 120 | 180 | 240 | 300 | 360 | 360 |
| Secure Residential Institutions | 105 | 230 | 460 | 690 | 920 | 1150 | 1380 | 1380 |
| Storage or Distribution | 50 | 175 | 350 | 525 | 700 | 875 | 1050 | 1050 |
|
*To receive a rating of A0, buildings must also meet the criteria for Zero Emissions Building (ZEB) as defined in regulations, and differing for each building type. |
||||||||
Tables 1-10 only include the latest BER published for each building i.e. the BER is on the public register.
Table 1 classifies the number of BER certificates by energy rating and building type. This relates to the current building use and it is displayed on the BER certificate. Some building types have been combined for the purposes of this release e.g. schools and colleges.
Table 2 profiles Building Energy Ratings by type of main space heating system fuel. The heating system fuel options are: Mains gas; Heating Oil; Electricity; LPG; Biogas; Oil; Coal; Biomass; Waste heat; Anthracite; Smokeless fuel; Dual fuel appliances; and Other. Categories with only a small number of responses have been amalgamated in Table 2.
Tables 3-4 cross-classify main space heating system fuel by county and building type.
Table 5 cross-classifies main ventilation system by building type.
Table 6 shows the average floor area by building type and county.
Tables 7-8 show the average primary energy use and average carbon dioxide figures by building type and county.
Table 9 shows the relationship between period of construction and building energy ratings. It can be linked with changes to the Building Regulations that require new buildings to be more energy efficient.
Table 10 cross-classifies main space heating fuel by period of construction.
We are currently reviewing the format of this release. Any feedback from readers of this release is welcome.
Learn about our data and confidentiality safeguards, and the steps we take to produce statistics that can be trusted by all.